| OCR Text |
Show Existing Structures, 111-115 25th Street Buildings Constructed in lSS9-90 FloorCeiling Roan Ceiling Width Framing Basement 7'-6 11 £ lS'-l" at brick First floor 16'-0" 19'-10" 2x12" @ 16" o/c with X-bracing @ 1/3 spans 16 J -1H 20'-9" Floor of Building Roof Framing & Misc. Notes III 25th One-story addition Second floor 12' -O"± 2x12" @ 12" o/c with X-bracing @ 1/3 spans 2x14" @ 16" o/c with X-bracing @ 1/3 spans basanent floor is concrete floor is concrete slab 21' -5"± 2xS" (?) at 12" olc with X-bracing @ 1/3 spans probably similar to 115 25th 1" roof sheathing is intact but roofing is all missing. 115 25th Basement 7'-11" 19'-10" 2xl2" @ 16" o/c at wi bracing brick First floor 15'-4" 22'-1~" Second floor 12'-9~" 22'=11" Third floor 10'-8" 22'-9~" floor is concrete slab 2xl4" @16" o/c wi bracing no bearing wall 2xl4" @ 16" o/c bracing bearing wall 9' -3" fran west brick wall wi 2x6" @ 16" ole bracing wi 2xS" @ 24" o/c with be6" diag. bracing every 4' Note: Sate of the structural lumber has deteriorated due to water damage and may be unsuitable for reuse. Parts of the second and first floors in III 25th St. have collapsed due to deterioration and loading fran snow inside the building. |