OCR Text |
Show configuration is shown in Figure 22 - one injector only for each burner, each with a bifurcated jet nozzle. Our experience with this installation demonstrated the flexibility of the LNI technique. INJECTOR 71/2° D O W N FLUE D O O R DOOR Figure 22 NOx and specific fuel consumption targets were both met with this arrangement, and a successful compliance test completed. Direct Charged Aluminum Melter, Norway The furnace is a rectangular, tilting, 30 ton capacity, 10 ton/h melt rate, unit charged with 70% extrusion scrap, 30 % ingot, having dimensions of 25' wide, 17' deep, and 8' high, and is shown in Figure 23. Figure 23 18 |