Show agencies to perform a risk assessment and detailed testing each time the facility is operated. The results are found in Tables 14-17. Table 14 Ogden Environmental Services, Inc. Circulating Bed Combustor, La Jolla, CA * (May, 1984) POHC ORE Freon113 99.993 CCI4 99.9997 C6CI6 99.9998 ethylben- 99.9986 zene xylene 99.9969 trichloro- 99.974 benzene toluene 96.15 SF6 94.765 TUHC ppm 96 Particulates 02 (gr/OSCF) 0/0 T CO deg.F ppm resid. t sec 6.3 1501 907 2.19 * Note: these tests were performed under "failure" conditions on purpose Note in Table 14 that these tests were performed under operating conditions that were designed for a "failure" of the combustor. However, the tests indicate that the Destruction and Removal Efficiency criteria are still met for most of the compounds. One compound, SF6, has traditionally given low DREIs, primarily because of its refractory nature with respect to oxidation. Toluene has traditionally been found to be a stable product of reformation( 1) in full-scale hazardous waste combustors. Therefore, it is normally not a good choice as a POHe because credit is not given for destroying the products of reformation when calculating DRE. 1 7 |