OCR Text |
Show Table 4 Rhone-Poulenc Basic Chern.Co. (formerly Stauffer Chem. Co.) Carson, CA (March, 1985) POHC ORE HCI (%) Particulates 02 T reside % removal (gr/OSCF) 0/0 deg.F time(s) "Normal" Condition CCI4 >99.99996 >99.998 0.01618 1.95 1826 3.98 1,1,1 TCA 99.99994 pentachloro-phenol >99.99994 1,2,4 trichloro-benzene> 99.99987 "Upset" Condition CCI4 99.99999 >99.999 1.5 1690 4.86 These research results also indicate that the Rhone-Poulenc furnace can pass the three RCRA performance standards (by wide margins, in fact). The other two commercial combustion proposals are not yet built, Chemical Waste Management and CTTS, so data are not yet available. ON-SITE FACILITIES: Most of the on-site facilities have test results available. The exception is the Dow facility in Pittsburg, California. This facility has three "thermal oxidizers" that are classified as industrial furnaces, and a proposal that is in the permitting process for a new rotary kiln incinerator . 7 |