Publication Type |
Journal Article |
School or College |
College of Social & Behavioral Science |
Department |
Psychology |
Creator |
Drews, Frank; Westenskow, Dwayne R.; Bermudez, Julio Cesar; Syroid, Noah Daniel; Agutter, James A.; Strayer, David Lee |
Other Author |
Albert, Rob; Weinger, Matthew B. |
Title |
Evaluation of a cardiovascular display in a high fidelity simulator |
Date |
2003 |
Description |
Human error in anesthesia can be attributed to misleading information from patient monitors or to the physician's failure to recognize a pattern. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. We designed a graphic display to show hemodynamic variables. Twenty anesthesiologists were asked to assume care of a simulated patient. Half the participants used the graphic cardiovascular display; the other half used a Datex As/3 monitor. One scenario was a total hip replacement with a transfusion reaction to mismatched blood. The second scenario was a radical prostatectomy with 1.5 L of blood loss and myocardial ischemia. Subjects who used the graphic display detected myocardial ischemia 2 min sooner than those who did not use the display. Treatment was initiated sooner (2.5 versus 4.9 min). There were no significant differences between groups in the hip replacement scenario. Systolic blood pressure deviated less from baseline, central venous pressure was closer to its baseline, and arterial oxygen saturation was higher at the end of the case when the graphic display was used. The study lends some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnose, manage, and treat critical cardiovascular events in a simulated environment. |
Type |
Text |
Publisher |
Wolters Kluwer (LWW) |
First Page |
1403 |
Last Page |
1413 |
Subject |
Patient monitors; Visual information; Graphic displays |
Subject LCSH |
Anesthesia; Anesthetic emergencies; Medical informatics |
Language |
eng |
Bibliographic Citation |
Drews, F., Agutter, J., Syroid, N. D., Westenskow, D. R., Albert, R. W., Strayer, D. L., Bermu dez, J. C., & Weinger, M. B. (2003). Evaluation of a graphical cardiovascular display in a high fidelity simulator. Anesthesia & Analgesia, 97, 1403-13. |
Rights Management |
(c) Wolters Kluwer (LWW) |
Format Medium |
application/pdf |
Format Extent |
437,255 Bytes |
Identifier |
ir-main,2667 |
ARK |
ark:/87278/s6rb7p7v |
Setname |
ir_uspace |
ID |
707280 |
Reference URL |
https://collections.lib.utah.edu/ark:/87278/s6rb7p7v |