Page 36

Update Item Information
Title Support Activities for the Edgewater Coolside Process Demonstration
Creator Stouffer, M. R.; Wu, M. M.; Yoon, H.; Winschel, R. A.
Publisher Digitized by J. Willard Marriott Library, University of Utah
Date 1988
Spatial Coverage presented at Pittsburgh, Pennsylvania
Abstract This paper describes lab and pilot scale experimental work done in support of the 105 MWe Coolside process demonstration at Ohio Edison's Edgewater Station. The demonstration project sponsors include DOE, the State of Ohio, Ohio Edison, Babcock and Wilcox, and Consolidation Coal Company (Consol). The Coolside process, scheduled for demonstration in early 1989, is an in-duct sorbent injection technology for 502 control. The process involves hydrated lime injection upstream of water spray flue gas humidification in a utility duct. The S02 capture and sorbent utilization can be improved through the injection of a water soluble add itive, such as sodium hydroxide, in the humidification water. Lab, pilot and field testing has shown S02 removals up to 80%. Economic analyses indicate particularly attractive 502 control costs in retrofit applications. As part of its participation in the Edgewater project, Con sol conducted experimental work to select candidate sorbents, to develop a test program, and to determine the chemical and physical characteristics of Coolside waste. Pilot scale (0.' MWe) Coolside tests of once-through and recycle operation were conducted to develop a performance data base for the demonstration. Based on the pi lot test results, two commercial hydrated limes were selected for use in the Edgewater demonstration tests. The waste characterization data indicate that the solid waste is suitable for landfill disposal in terms of compressive strength, permeability, reactivity with water, and the concentrations of trace elements, sulfate, and total dissolved solids in the leachates.
Type Text
Format application/pdf
Language eng
Rights This material may be protected by copyright. Permission required for use in any form. For further information please contact the American Flame Research Committee.
Conversion Specifications Original scanned with Canon EOS-1Ds Mark II, 16.7 megapixel digital camera and saved as 400 ppi uncompressed TIFF, 16 bit depth.
Scanning Technician Cliodhna Davis
ARK ark:/87278/s6s46vjt
Setname uu_afrc
ID 4849
Reference URL https://collections.lib.utah.edu/ark:/87278/s6s46vjt

Page Metadata

Title Page 36
Format application/pdf
OCR Text Show
Setname uu_afrc
ID 4847
Reference URL https://collections.lib.utah.edu/ark:/87278/s6s46vjt/4847