26 - 50 of 109
Number of results to display per page
CreatorTitleDescriptionSubjectDate
26 Normann, Richard A.Effects of GABA and related drugs on horizontal cells in the isolated turtle retinaThe role of GABA in the outer plexiform layer of the turtle retina has been examined by intracellular recordings from L- and C-type horizontal cells in the isolated retina preparation. GABA (1-5 mM) slightly depolarized the L-type horizontal cells, reduced the amplitude of their photoresponses, and ...Retina; Horizontal Cells; Synapse; Negative Feedback; GABA; Turtle1990
27 Christensen, Douglas A.; Andrade, Joseph D.Improved sensitivity in ellipsometry of thin biochemical films by employing sublayersEllipsometry is widely used for investigating the optical properties of thin films on planar substrates, including films of adsorbed proteins or polymers. The average thickness and effective refractive index of the adsorbed layer are calculated by measuring the A and ¥ ellipsometry parameters. Unfo...Biochemical films; SiO2 sublayer1990
28 Normann, Richard A.; Campbell, Patrick K.; Jones, Kelly E.100 electrode intracortical array: structural variabilityA technique has been developed for fabricating three dimensional "hair brush" electrode arrays from monocrystalline silicon blocks. Arrays consist of a square pattern of 100 penetrating electrodes, with 400 microns interelectrode spacing. Each electrode is 1.5mm in length and tapers from about 100 m...Microelectrode arrays; Stimulation; Micromachining1990
29 Normann, Richard A.; Campbell, Patrick K.; Jones, Kelly E.; Huber, Robert J.; Horch, Kenneth W.Silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode arrayA method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilit...Electric Stimulation; Electrodes, Implanted; Sensory Cortex; Intracortical Electrode Array1991
30 Horch, Kenneth W.Information extraction from peripheral nervesThis work is directed toward providing better rehabilitation for people suffering from somatosensory loss and paralysis due to spinal cord injury, head trauma, or stroke. The goal of this project is to demonstrate that information suitable for controlling prosthetic devices, modulating functional el...Peripheral nerve; Neural recordings; Intrafascicular electrodes1991
31 Horch, Kenneth W.Muscle recruitment with intrafascicular electrodesWe have studied muscle recruitment with Tefloninsulated, 25 pm diameter, Pt-Ir intrafasicular electrodes implanted in nerves innervating the gastrocnemius and soleus muscles of cats. The purpose of this study was to measure the performance of these bipolar electrodes, which had been designed to...Functional neuromuscular stimulation (FNS); Intrafascicular electrode1991
32 Gesteland, Raymond F.; Atkins, John F.Frameshifting in gene 10 of bacteriophage T7Gene 10 of bacteriophage T7, which encodes the most abundant capsid protein, has two products: a major product, 10A (36 kDa), and a minor product, 10B (41 kDa). 10B is produced by frameshifting into the -1 frame near the end of the 10A coding frame and is incorporated into the capsid. The frameshift...Frameshifting; Bacteriophage T7; RNA, Viral; Gene Expression1991
33 Christensen, Douglas A.FDTD modeling in the design of optical chemical sensor structuresThe finite-difference time-domain method (FDTD) is a numerical technique for solving Maxwell's equations in a discretized space and time frame. It has been used extensively in the analysis of electrically large structures in the microwave domain, but has only recently been applied to optical proble...Finite-difference time-domain method; Immunochemical fluorosensors; Planar waveguides1991
34 Horch, Kenneth W.Information contrained in sensory nerve recordings made with intrafascicular electrodesMultiunit recordings were made in anesthetized cats with chronically implanted intrafascicular electrodes over a period of six months. Neural signals recorded with these electrodes consisted of activity in sensory fibers innervating a variety of cutaneous mechanoreceptors. Mechanical stimuli wer...Intrafascicular electrodes; Functional electrical stimulation (FES); Closed-loop control1991
35 Christensen, Douglas A.Computer-aided design of two-dimensional electric-type hyperthermia applicators using the finite-difference time-domain methodA hyperthermia applicator design tool consisting of a finite-difference time-domain (FDTD) technique in combination with a graphical display of electric fields and normalized linear temperature rise is described. This technique calculates, rather than assumes, antenna current distributions; it incl...Finite-difference time-domain method; Hyperthermia applicator1991-09
36 Normann, Richard A.; Johansson,Torbjorn; Abbasi, Masoud; Huber, Robert J.Three-dimensional architecture for a parallel processing photosensing arrayA three-dimensional architecture for a photosensing array has been developed. This silicon based architecture consists of a 10 x 10 array of photosensors with 80 microns diameter, through chip interconnects to the back side of a 500 microns thick silicon wafer. Each photosensor consists of a 300 x 3...Retina; Optics; Silicon; Photosensing1992
37 Christensen, Douglas A.; Herron, James N.Evanescent coupling in a waveguide fluoroimmunosensorA key factor in the analysis of evanescently-coupled optical sensors, such as the planar waveguide immunosensor analyzed here, is the efficiency of coupling between the optical waveguide modes and the fluorescent sources located on the surface of the waveguide. This is an important parameter in dete...Evanescent coupling; Waveguide; Fluoroimmunosensor1992
38 Christensen, Douglas A.Laser diode coherence length variation with drive current: a tool for dispersion measurementsA visible light (670nm) laser diode was used as a variable coherence length source to measure dispersion characteristics in single-mode fibers. The diode's spectral width, measured against increasing drive current, was found to change from about 16 nanometers to less than 0.2 nanometer. The corresp...Laser diode; Fiber interferometry1992
39 Normann, Richard A.; Abbasi, Masoud; Johansson,TorbjornSilicon carbide enhanced thermomigrationThe widespread acceptance of thermomigration technology to produce through-chip interconnects has been impaired by (i) a random walk of the Si-Al liquid eutectic inclusion as it traverses the wafer, and (ii) a ?surface barrier? which allows thermomigration of only relatively large inclusions. In ...Silicon Dioxide; Thermometers; Transducers; Thermomigration Technology; Infrared Lamps1992
40 Christensen, Douglas A.Finite-difference time-domain modeling and experimental characterization of planar waveguide fluorescence sensorsThe finite-difference time-domain method (FDTD) is a powerful numerical technique for solving Maxwell's equations in a discretized space and time grid. Its applications have up to now been in the analysis of electrically large structures in the microwave domain, and the scope of investigations has b...Finite-difference time-domain method; Planar waveguide1992
41 Normann, Richard A.; Horch, Kenneth W.; Cha, KichulMobility performance with a pixelized vision systemA visual prosthesis, based on electrical stimulation of the visual cortex, has been suggested as a means for partially restoring functional vision in the blind. The prosthesis would create a pixelized visual sense consisting of punctate spots of light (phosphenes). The present study investigated the...Visual Prosthesis; Mobility; Phosphene Simulator1992
42 Horch, Kenneth W.Separation of action potentials in multiunit intrafascicular recordingsClassification of action potentials in multiunit recordings was based on the use of various types of features to uniquely characterize action potentials from different cells. We compared classification results obtained using three types of descriptive features: digitized data points, amplitude and ...Long-term implantable intrafascicular electrodes; Nerve recordings; Simulated neural data1992
43 Christensen, Douglas A.Extending the two-dimensional FDTD method to hybrid electromagnetic systems with active and passive lumped elementsThis paper extends the finite-difference time-domain (FDTD) method to include distributed electromagnetic systems with lumped elements (a hybrid system) and voltage and current sources. FDTD equations that include nonlinear elements like diodes and transistors are derived. Calculation of driving-p...Finite-difference time-domain method; Lumped elements1992-04
44 Horch, Kenneth W.Selective activation of functional muscle groups through stimulation of spinal motor poolsA microelectrode was used to stimulate motor neurons in the lumbo-sacral spinal cord of adult cats. Consistent with spinal cord anatomical studies, we found that the motor neurons responsible for activation of individual muscle groups are situated together in specific areas of the cord, forming mot...Spinal motor pools1993
45 Christensen, Douglas A.; Herron, James N.Comparison of robust coupling techniques for planar waveguide immunosensorsWe have analyzed and fabricated two different coupling schemes to meet the requirements for a convenient means of coupling into a planar waveguide immunosensor that is relatively insensitive to beam alignment. These are the "launch" coupler and the grating coupler. Each possesses advantages and dis...Planar waveguide immunosensors; Fluorescence; Launch coupler; Grating coupler1993
46 Horch, Kenneth W.Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodesWe have studied activation of newe fibers by pairs of Pt-Ir wire electrodes implanted within single fascicles of the nerve innervating the gastrocnemius muscle in cats. The purpose of this study was to determine if these intrafascicular electrodes can activate nerve fibers in different fascicles...Functional electrical stimulation; Intrafascicular stimulation; Silicon electrode array1993
47 Gesteland, Raymond F.; Weiss, Robert B.Efficient shine- Dalgarno sequence but not translation is necessary for LacZ mRNA stability in Escherichia coliThe 5' ends of many bacterial transcripts are important in determining mRNA stability. A series of Shine-Dalgarno (SD) sequence changes showed that the complementarity of the SD sequence to the anti-SD sequence of 16S rRNA correlates with lacZ mRNA stability in Escherichia coli. Several initiation c...Protein Biosynthesis; Ribosomes; Escherichia coli; Shine-Dalgarno Sequence1994
48 Gesteland, Raymond F.; Ives, Jeffrey T.; Stockham, Thomas G.Automated film reader for DNA sequencing based on homomorphic deconvolutionAn automated reader for electrophoresis based DNA sequencing methods is described that provides fast and accurate sequence determination. Digitized sequencing lanes are processed with homomorphic blind deconvolution in preparation for peak detection, interlane alignment, peak refinement and base cal...Sequence Analysis; Electrophoresis; Automated Film Reader; Homomorphic Deconvolution1994
49 Gesteland, Raymond F.; Atkins, John F.; Tuohy, Therese M.Uninterrupted translation through putative 12-nucleotide coding gap in sequence of carA: business as usualPrevious work of others reported an untranslated stretch of 12 nucleotides in the 5' coding sequence of carA from Pseudomonas aeruginosa. However, N-terminal protein sequencing of carA-lacZ translational fusions shows that these 12 nucleotides are normally translated in a continuous triplet manner, ...Base Sequence; Protein Biosynthesis; Sequence Deletion1994
50 Horch, Kenneth W.Mechanical testing of metallic and polymeric intrafascicular electrodesWe are exploring alternatives to Pt/Ir wire for constructing ultra-flexible neural intrafascicular electrodes suitable for chronic implantation. In this study we measured the flexural properties of several kinds of fine metal wires and conducting polymer fibers. The fibers were made either of in...Intrafascicular electrodes; Polymer fibers1994
26 - 50 of 109