![]() | Saam, Brian | 3He spin exchange cells for magnetic resonance imaging | We present a protocol for the consistent fabrication of glass cells to provide hyperpolarized (HP) 3He for pulmonary magnetic resonance imaging. The method for producing HP 3He is spin-exchange optical pumping. The valved cells must hold of order 1 atm.L of gas at up to 15 atm pressure. Because char... | 3He; Spin exchange cells; Hyperpolarized 3He; Pulmonary magnetic resonance imaging; Spin-exchange optical pumping; SEOP; Glass cells | 2002 |
2 |
![]() | Saam, Brian | Low-field orientation dependence of 3He relaxation in spin-exchange cells | We have observed a significant dependence of 3He longitudinal relaxation times in glass spin-exchange optical pumping (SEOP) cells due only to the physical orientation of the cell in a 3 mT (30 G) applied magnetic field. The cells had no previous exposure to higher fields or were thoroughly degau... | Spin-exchange optical pumping; SEOP; 3He; Hyperpolarized noble gases; Longitudinal spin-relaxation; MEOP; Low-field orientation | 2004-02 |
3 |
![]() | Saam, Brian | Wall relaxation of 3He in spin-exchange cells | The 3He longitudinal spin-relaxation rate T1-1 is crucial for production of highly polarized 3He by spin-exchange optical pumping. We show that T1-1 is increased by a factor of 2-20 solely by exposure of spin-exchange cells to a few-kG magnetic field. The original T1-1 can be restored by degaussing ... | Wall relaxation; Spin-exchange cells; 3He; Longitudinal spin-relaxation; Spin-exchange optical pumping; SEOP; Hyperpolarized 3He; Surface magnetism; Glass cells | 2001-09 |