1 - 25 of 84
Number of results to display per page
CreatorTitleDescriptionSubjectDate
1 Dwight, Zachary LawrenceuAnalyze: web-based high-resolution DNA melting analysis with comparison to thermodynamic predictionsAbstract-uAnalyzeSM is a web-based tool for analyzing high-resolution melting data of PCR products. PCR product sequence is input by the user and recursive nearest neighbor thermodynamic calculations used to predict a melting curve similar to uMELT (http://www.dna.utah.edu/umelt/umelt.html). Unproce...2012-01-01
2 Dwight, Zachary LawrenceHeterozygote PCR product melting curve predictionMelting curve prediction of PCR products is limited to perfectly complementary strands. Multiple domains are calculated by recursive nearest-neighbor thermodynamics. However, the melting curve of an amplicon containing a heterozygous single nucleotide variant (SNV) after PCR is the composite of four...2014-01-01
3 Planelles, VicenteKinase control of latent HIV-1 infection: PIM-1 kinase as a major contributor to HIV-1 reactivationDespite the clinical relevance of latent HIV-1 infection as a block to HIV-1 eradication, the molecular biology of HIV-1 latency remains incompletely understood. We recently demonstrated the presence of a gatekeeper kinase function that controls latent HIV-1 infection. Using kinase array analysis w...2014-01-01
4 Wittwer, Carl T.Influence of PCR reagents on DNA polymerase extension rates measured on real-time PCR instrumentsBACKGROUND: Radioactive DNA polymerase activity methods are cumbersome and do not provide initial extension rates. A simple extension rate assay would enable study of basic assumptions about PCR and define the limits of rapid PCR. METHODS: A continuous assay that monitors DNA polymerase extension us...2014-01-01
5 Wittwer, Carl T.Genotyping accuracy of high-resolution DNA melting instrumentsHigh-resolution DNA melting is a closed-tube method for genotyping and variant scanning that depends on the thermal stability of PCR-generated products. Instruments vary in thermal precision, sample format, melting rates, acquisition, and software. Instrument genotyping accuracy has not been assesse...2014-01-01
6 Rockwood, Alan L.Performance enhancement in the measurement of 5 endogenous steroids by LC-MS/MS combined with differential ion mobility spectrometryBackground: Challenges for steroid analysis by LC-MS/MS include low ionization efficiency, endogenous isobars with similar fragmentation patterns and chromatographic retention. Differential ion mobility spectrometry (DMS) provides an additional degree of separation prior to MS/MS detection, and show...2014-01-01
7 Hansen, Mark S.; Coffin, Cheryl M.; Capecchi, Mario R.Pax3:Fkhr interferes with embryonic Pax3 and Pax7 function: implications for alveolar rhabdomyosarcoma cell of origin.To investigate the role of the translocation-associated gene Pax3:Fkhr in alveolar rhabdomyosarcomas, we generated a Cre-mediated conditional knock-in of Pax3:Fkhr into the mouse Pax3 locus. Exploring embryonic tumor cell origins, we replaced a Pax3 allele with Pax3:Fkhr throughout its expression do...Neuroprogenitor; Embryogenesis2004-11-01
8 Eichwald, Ernst; Capecchi, Mario R.; Thomas, Kirk R.Mouse model for the delta F508 allele of cystic fibrosisThe most common cause of cystic fibrosis is a mutation that deletes phenylalanine 508 in cystic fibrosis transmembrane conductance regulator (CFTR). The delta F508 protein is misprocessed and degraded rather than traveling to the apical membrane. We used a novel strategy to introduce the delta F508 ...Digestive System; Disease Models, Animal; Electrolytes; Mice, Inbred C57BL1995-10
9 Coffin, Cheryl M.; Capecchi, Mario R.Alveolar rhabdomyosarcomas in conditional Pax3:Fkhr mice: cooperativity of Ink4a/ARF and Trp53 loss of function.Alveolar rhabdomyosarcoma is an aggressive childhood muscle cancer for which outcomes are poor when the disease is advanced. Although well-developed mouse models exist for embryonal and pleomorphic rhabdomyosarcomas, neither a spontaneous nor a transgenic mouse model of alveolar rhabdomyosarcoma has...Cell Differentiation; Forkhead Transcription Factors; Myogenic Regulatory Factors2004-11-01
10 Hymas, Weston C.; Hillyard, David R.Description and validation of a novel real-time RT-PCR enterovirus assayEnteroviruses are a leading cause of aseptic meningitis in adult and pediatric populations. We describe the development of a real-time RT-PCR assay that amplifies a small target in the 5' nontranslated region upstream of the classical Rotbart enterovirus amplicon. The assay includes an RNA internal ...RT-PCR enterovirus assay; Rotbart enterovirus amplicon; Aseptic meningitis2008
11 Digre, Kathleen B.; Gouw, Launce G.; Harris, Catherine P.; Haines, John H.; Ptacek, L.J.Autosomal dominant cerebellar ataxia with retinal degeneration: clinical, neuropathologic, and genetic analysis of a large kindred.The autosomal dominant cerebellar ataxias (ADCA) comprise a heterogeneous group of neurologic disorders characterized by degeneration of the cerebellum, spinal cord, and brainstem. Genetic analysis has revealed two loci, SCA1 on chromosome 6p, and SCA2 on chromosome 12q, responsible for some ADCA. W...Retinal Degeneration; Cerebellar Ataxia; Genetic Analysis1994-08
12 Singleton, J. Robinson; Smith, A. GordonMicrovascular complications of impaired glucose tolerance.Impaired glucose tolerance (IGT) serves as a marker for the state of insulin resistance and predicts both large- and small-vessel vascular complications, independent of a patient's progression to diabetes. Patients with IGT are at significantly increased risk for death and morbidity due to myocardia...Microcirculation; Humans2003-12-01
13 Owen, William E.; Roberts, William L.Performance characteristics of eight estradiol immunoassaysMeasurement of estradiol is useful in assisted reproduction, evaluation of infertility, menopause, and male feminization. The analytic performance of 8 estradiol immunoassays was evaluated. The imprecision and accuracy of the Access, ADVIA Centaur, ARCHITECT i2000, AutoDELFIA, Elecsys 2010, IMMULI...Estradiol immunoassays2004
14 Owen, William E.; Roberts, William L.Performance characteristics of four automated natriuretic peptide assaysMeasurement of circulating B-type natriuretic peptide (BNP) and N-terminal proBNP (NT-proBNP) can identify patients with heart failure and guide therapy. The limit of detection, linearity, imprecision, method comparison, analytic concordance, and reference intervals of the Access 2 BNP (Biosite, San...Natriuretic peptide assays; BNP2005
15 Jaskowski, Troy D.Comparison of capillary zone and immunosubtraction with agarose gel and immunofixation electrophoresis for detecting and identifying monoclonal gammopathiesCapillary zone electrophoresis (CZE) and immunosubtraction electrophoresis (ISE) were evaluated for ability to detect and immunotype monoclonal proteins, compared with agarose gel electrophoresis (AGE) and immunofixation electrophoresis (IFE), respectively. Six hundred seventeen serum samples wer...Capillary zone electrophoresis; Immunosubtraction electrophoresis; CZE; ISE; Monoclonal protein electrophoresis; Serum protoin electrophoresis; Agarose gel; Dysproteinemias1999
16 Owen, William E.; Roberts, William L.Comparison of five automated serum and whole blood folate assaysSerum and whole blood folate measurements are used to establish folate deficiency. Most methods used in clinical laboratories are automated, nonisotopic methods that use folate-binding protein. Linearity, imprecision, and method comparison studies, including serum and whole blood hemolysates, wer...Folate assays; Serum folate; Whole blood folate; Automated assays2003
17 Owen, William E.; Roberts, William L.Performance characteristics of four immunonephelometric assays for the quantitative determination of IgA and IgM in cerebrospinal fluidMeasurement of IgA and IgM in cerebrospinal fluid (CSF) can be useful in the diagnosis of multiple sclerosis and other central nervous system disorders. The Dade Behring (Deerfield, IL) N Latex IgA and N Latex IgM tests on the BN II System and Beckman Coulter (Brea, CA) low-concentration IgA an...IgA; IgM; Immunonephelometric assays; Imprecision; Method comparison; Reference interval2003
18 Jaskowski, Troy D.Determination of cytokine responses using a multiplexed fluorescent microsphere immunoassayWe used a multiplexed fluorescent microsphere immunoassay to develop a sandwich capture assay to assess simultaneously the production of thymus helper (TH) 1- and TH2-type cytokines in tissue culture supernatant obtained from stimulated peripheral blood mononuclear cells. The assay then was use...Multiplexed fluorescent microsphere immunoassay2002
19 Smith, A. Gordon; Singleton, J. RobinsonLifestyle intervention for pre-diabetic neuropathy.OBJECTIVE: The purpose of this study was to evaluate intraepidermal nerve fiber density (IENFD) as a sensitive measure of neuropathy change in patients with neuropathy associated with impaired glucose tolerance (IGT) receiving lifestyle intervention based on that used in the Diabetes Prevention Prog...Older people; Biopsy; Blood Pressure; Body Mass Index; Cholesterol; Diabetic Diet2006-06-29
20 Liew, Michael; Erali, Maria; Page, Sam; Hillyard, David R.; Wittwer, Carl T.Hepatitis C genotyping by denaturing high-performance liquid chromatographyDetermination of the hepatitis C virus (HCV) genotype for infected patients increasingly has become accepted as the standard of care. Genotype assignment helps in assessing disease prognosis and assists in establishing the appropriate duration of treatment. The great genetic diversity of HCV, with 1...Base Sequence; 5' Untranslated Regions; Genotype; Hepacivirus; Molecular Sequence Data2004-01
21 Jaskowski, Troy D.Diagnostic performance of phospholipid-specific assays for the evaluation of antiphospholipid syndromeThe diagnostic performance of commercially available nonstandard antiphospholipid (aPL) assays for the evaluation of antiphospholipid syndrome (APS) is unknown. In 62 patients with APS, 88 with recurrent pregnancy loss, 50 healthy blood donors, and 24 women with one or more successful pregnancies, w...APS; Phospholipid-specific assays; Diagnostic performance2008-06-01
22 Jaskowski, Troy D.Screening for antinuclear antibodies by enzyme immunoassayIndirect fluorescent antibody (IFA) is the most widely used method in clinical laboratories to screen for autoantibodies against a wide variety of nuclear antigens. Recently, a number of antinuclear antibody (ANA) enzyme immunoassay (EIA) screens have become commercially available and claim to be an...Antinuclear antibodies; Enzyme immunoassay1996
23 Owen, William E.; Roberts, William L.Comparable effects of DIGIBIND and DigiFab in thirteen digoxin immunoassaysDigoxin is widely prescribed for the treatment of cardiac conditions (1). Because of its narrow therapeutic range, digoxin-related toxicity resulting from acute or chronic overdose is common. Metabolites of digoxin as well as related compounds, including digitoxin, tanshinones, bufandienolide, a...DIGIBIND; DigiFab; Digoxin immunoassays; Digoxin toxicity2002
24 Jaskowski, Troy D.Comparison of four enzyme immunoassays with a western blot assay for the determination of type-specific antibodies to herpes simplex virusMost current enzyme immunoassays (EIAs) differentiate inadequately between types 1 and 2 herpes simplex virus (HSV) antibodies since significant crossreactivity exists. We compared 4 IgG type-specific EIAs using a Western blot assay for resolution of discrepant results. The Diamedix had sensitivit...Enzyme immunoassays; Western blot assay; Type-specific antibodies2001
25 Jaskowski, Troy D.Multiplex analysis of heterophil antibodies in patients with indeterminate HIV immunoassay resultsWe hypothesized that heterophil antibodies reactive with animal proteins used in blot preparation caused nonspecific staining (NSS) on HIV Western blot (WB) studies, causing indeterminate results. We analyzed samples showing NSS on HIV WB using a multiplexed immunoassay to simultaneously measur...Heterophil antibodies; Heterophil interference; Multiplex analysis; False-positive HIV enzyme-linked immunosorbent assay; ELISA2001
1 - 25 of 84