OCR Text |
Show Table 2 Sensitivity of NO Emissions to Burner Operating Conditions Burner Zone Burner Stoichiometry Burner Settings CCV high medium Directional Flame med high TSV high high The TSV burner is being installed in an industrial Turbo furnace. Demonstration tests of the TSV burner in the Turbo furnace will be conducted in January 1984. The CCV burner with tertiary air is being installed in an industrial wall-fired furnace, also scheduled for start up in 1984. REFERENCES 1. C. A. Penterson, "Development of an Economical Low-NOx Firing System for Coal-fired Steam Generators," 1982 Joint Power Conference. 2. T. C. Claypole, N. Syred, "The Effect of Swirl Burner Aerodynamics on N0X Formation," Eighteenth Symposium on Combustion, The Combustion Institute, 1981. 3. P. A. Roberts, "Near Field Aerodynamics Research Program," International Flame REsearch Foundation, 1983. 4. A. H. Rawdon, S. A. Johnson, "Application of N0X Control Technology to Power Boilers," 1973 American Power Conference. 5. R. A. Lisauskas, A. H. Rawdon, "Status of N0X Control for Riley Stoker Wall-fired and Turbo Furnaces," EPA-EPRI Joint Symposium on Stationary Combustion N0X Control, 1982. 6. R. A. Lisauskas, J. J. Marshall, "An Evaluation of N0X Emissions from Coal-fired Steam Generators," 1980 EPA/EPRI Joint Symposium on Stationary Combustion N0X Control. 15 |