| Publication Type | journal article |
| Department | Pathology |
| Program | ARUP Institute for Clinical and Experimental Pathology |
| Creator | Jaskowski, Troy D. |
| Other Author | Martins, Thomas B.; Pasi, Brian M.; Pickering, Jerry W.; Litwin, Christine M.; Hill, Harry R. |
| Title | Determination of cytokine responses using a multiplexed fluorescent microsphere immunoassay |
| Date | 2002 |
| Description | We used a multiplexed fluorescent microsphere immunoassay to develop a sandwich capture assay to assess simultaneously the production of thymus helper (TH) 1- and TH2-type cytokines in tissue culture supernatant obtained from stimulated peripheral blood mononuclear cells. The assay then was used to assess the cytokine production of patients with hyperimmunoglobulinemia E syndrome and in cord blood from neonates. The multiplexed assay has a reportable range of less than 10 to 50,000 pg/mL. For linearity and recovery studies, R2 values for the 6 cytokines ranged from 0.988 to 0.999 for samples spiked with known concentrations of recombinant cytokine standards and for patient samples. The assay showed good specificity, with little cross-reactivity between cytokines. Results from supernatants of Staphylococcus aureus-stimulated peripheral blood mononuclear cells obtained from 6 patients with hyperimmunoglobulinemia E syndrome showed significantly less interferon (IFN)-gamma production than cells from healthy control subjects. Cord blood cells from neonates produced significantly less interleukin 12 and IFN-gamma than cells from adults in group B streptococci-stimulated mononuclear cells. The fluorescent multiplexed microsphere immunoassay can be used to quantitate multiple cytokines from 1 sample and should be useful for further understanding of the cytokine role in disease. |
| Type | Text |
| Publisher | American Society for Clinical Pathology |
| Volume | 118 |
| Issue | 3 |
| First Page | 346 |
| Last Page | 353 |
| Subject | Multiplexed fluorescent microsphere immunoassay |
| Subject LCSH | Cytokines; Immunoassay; Immunodeficiency |
| Language | eng |
| Bibliographic Citation | Martins, T. B., Pasi, B. M., Pickering, J. W., Jaskowski, T. D., Litwin, C. M., & Hill, H. R. (2002). Determination of cytokine responses using a multiplexed fluorescent microsphere immunoassay. American Journal of Clinical Pathology, 118(3), 346-53. |
| Rights Management | ©1996-2010 American Society for Clinical Pathology and ©1996-2010 ASCP Press |
| Format Medium | application/pdf |
| Format Extent | 112,482 bytes |
| Identifier | ir-main,11448 |
| ARK | ark:/87278/s6k36c4f |
| Setname | ir_uspace |
| ID | 705641 |
| Reference URL | https://collections.lib.utah.edu/ark:/87278/s6k36c4f |