Glistenings with long-term follow-up of the Surgidev B20/20 polymethylmethacrylate intraocular lens

Update Item Information
Publication Type Journal Article
School or College School of Medicine
Department Ophthalmology
Creator Olson, Randall J.
Other Author Wilkins, Edmond
Title Glistenings with long-term follow-up of the Surgidev B20/20 polymethylmethacrylate intraocular lens
Date 2001-10
Description PURPOSE: To compare patient satisfaction with vision 12 months after implantation of a silicone or acrylic foldable intraocular lens (IOL). SETTING: John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS: Selection criteria included patients who had uneventful cataract extraction by phacoemulsification with a temporal clear corneal incision or superior scleral tunnel incision, a curvilinear capsulorhexis, and in-the-bag IOL placement. One hundred sixty-two patients surveyed had a mean follow-up of approximately 15 months (range 12 to 18 months). Patients were divided into 3 groups of 54 each based on IOL type: AMO SI-30/40, Alcon MA30BA, and Alcon MA60BA. All patients were surveyed over the telephone using a standardized questionnaire protocol. They were questioned about their perception of vision with best optical correction in relation to visual blurring symptoms, glare symptoms, night vision, near vision, and overall vision. RESULTS: There were no significant differences in patient satisfaction among the 3 IOL groups in visual blurring or night vision. Patients in the SI-30/40 and MA60BA groups reported significantly higher satisfaction with glare symptoms, near vision, and overall satisfaction than patients in the MA30BA group. CONCLUSION: The SI-30/SI-40 and the MA60BA IOLs received significantly higher patient satisfaction scores than the MA30BA IOL in glare symptoms, near vision, and overall satisfaction.
Type Text
Publisher Elsevier
Volume 132
Issue 5
First Page 783
Last Page 785
Subject Phacoemulsification; Lens Implantation, Intraocular; Glare
Subject MESH Acrylic Resins; Biocompatible Materials; Visual Acuity
Language eng
Bibliographic Citation Wilkins E, Olson RJ. (2001). Glistenings with long-term follow-up of the Surgidev B20/20 polymethylmethacrylate intraocular lens. Am J Ophthalmol, 132(5), 783-5
Rights Management (c) Elsevier DOI: [place doi for article here]; http://dx.doi.org
Format Medium application/pdf
Identifier ir-main,3354
ARK ark:/87278/s6j10mgj
Setname ir_uspace
ID 704330
Reference URL https://collections.lib.utah.edu/ark:/87278/s6j10mgj
Back to Search Results