Mathematical description of causative factors and prevention of elevated intraocular pressure after keratoplasty

Update Item Information
Publication Type Journal Article
School or College School of Medicine
Department Ophthalmology
Creator Olson, Randall J.
Other Author Kaufman, Herbert E.
Title Mathematical description of causative factors and prevention of elevated intraocular pressure after keratoplasty
Date 1977-12
Description In keratoplasty with grafts the same size as the recipient bed, tight sutures and thick recipient corneal periphery distort the angle and may collapse the filtering meshwork. This can cause very high postoperative pressures, which can be avoided by the use of donor grafts larger than the recipient bed. These relationships can be mathematically predicted.
Type Text
Publisher Association for Research in Vision and Ophthalmology
Volume 16
Issue 12
First Page 1085
Last Page 1092
Subject Keratoplasty; Trabecular Collapse; Angle Disrottion; Elevated Pressure; Aphakia; Mathematics
Subject MESH Mathematics; Postoperative Complications; Corneal Transplantation; Suture Techniques
Language eng
Bibliographic Citation Olson RJ; Kaufman HE. A mathematical description of causative factors and prevention of elevated intraocular pressure after keratoplasty. Invest Ophthalmol Vis Sci. 1977 Dec;16(12):1085-92. Retrieved on November 13, 2007 from http://www.ncbi.nlm.nih.gov/sites/entrez
Rights Management (c) Association for Research in Vision and Ophthalmology
Format Medium application/pdf
Identifier ir-main,2069
ARK ark:/87278/s64464zm
Setname ir_uspace
ID 705805
Reference URL https://collections.lib.utah.edu/ark:/87278/s64464zm
Back to Search Results