We used a multiplexed fluorescent microsphere immunoassay to develop a sandwich capture assay to assess simultaneously the production of thymus helper (TH) 1- and TH2-type cytokines in tissue culture supernatant obtained from stimulated peripheral blood mononuclear cells. The assay then was used to assess the cytokine production of patients with hyperimmunoglobulinemia E syndrome and in cord blood from neonates. The multiplexed assay has a reportable range of less than 10 to 50,000 pg/mL. For linearity and recovery studies, R2 values for the 6 cytokines ranged from 0.988 to 0.999 for samples spiked with known concentrations of recombinant cytokine standards and for patient samples. The assay showed good specificity, with little cross-reactivity between cytokines. Results from supernatants of Staphylococcus aureus-stimulated peripheral blood mononuclear cells obtained from 6 patients with hyperimmunoglobulinemia E syndrome showed significantly less interferon (IFN)-gamma production than cells from healthy control subjects. Cord blood cells from neonates produced significantly less interleukin 12 and IFN-gamma than cells from adults in group B streptococci-stimulated mononuclear cells. The fluorescent multiplexed microsphere immunoassay can be used to quantitate multiple cytokines from 1 sample and should be useful for further understanding of the cytokine role in disease. |
Type |
Text |
Publisher |
American Society for Clinical Pathology |
Volume |
118 |
Issue |
3 |
First Page |
346 |
Last Page |
353 |
Subject |
Multiplexed fluorescent microsphere immunoassay |
Subject LCSH |
Cytokines; Immunoassay; Immunodeficiency |
Language |
eng |
Bibliographic Citation |
Martins, T. B., Pasi, B. M., Pickering, J. W., Jaskowski, T. D., Litwin, C. M., & Hill, H. R. (2002). Determination of cytokine responses using a multiplexed fluorescent microsphere immunoassay. American Journal of Clinical Pathology, 118(3), 346-53. |
Rights Management |
©1996-2010 American Society for Clinical Pathology and ©1996-2010 ASCP Press |
Format Medium |
application/pdf |
Format Extent |
112,482 bytes |
Identifier |
ir-main,11448 |
ARK |
ark:/87278/s6k36c4f |
Setname |
ir_uspace |
ID |
705641 |
Reference URL |
https://collections.lib.utah.edu/ark:/87278/s6k36c4f |