OCR Text |
Show Feature 12. Traversable probes (a) Local velocity, mean and turbulent fluctuations (b) Local mean velocity and static pressure (c) Local temperature, mean and turbulent fluctuations (d) Local mean temperat~re (e) Local mean oxygen partial pressure (f) Irradiance (hemispherical incident radiant flux density, W/m2) (g) Gas composition 13. Gas analysis (a) Oxygen ( C) CO2, CO, H20, CH4 ' CH20, total HC (d) Many components (e) Many components 14. Data acquisition (a) Dedicated to furnace (b) Dedicated to specific probes 15. Housing . Specifications 1 TSI laser-doppler velocimeter (LDV), with fibreoptic probe and IFRF cooling shroud 1 IFRF 5-hole probe 2 CAGCT microthermocouple probes 1 IFRF suction pyrometer (aspirating thermocouple probe) 1 CAGCT zirconia electrochemical probe 1 IFRF elliptical radiometer 1 CAGCT gas sampling probe 1 analyser with zirconia sensor, always on-line 1 analyser using chemiluminescence, always on-line 1 mUltigas analyser, based on ir and acoustic principles, always on-line 1 FTIR (Fourier transform, infrared) analyser, available when needed 1 gas chromatograph, available when needed 1 microcomputer and 1 Scimetrics board 1 microcomputer each for LDV, 5-hole probe, and microthermocouple Dedicated off-campus laboratory, on Grant Timmins Drive in Kingston Industrial Park |