OCR Text |
Show Table 1. Utility Testing Item No. Date Power Plant, Unit No. Unit Size Boiler Type Number of Burner Remarks MW Burners and Type Pulverizers 1 March 1994 Alabama Power 270 B& W opposed fired 18/6 pulv B&W DRB-XCL 3 rows x 3 burners staggered, E.C.Gaston Steam Plant, Unit 3 2 division walls one pulv. per row 2 --. -- same, Unit 1 270 B&W opposed fired 18/6:pulv B&W circular bnr 3 rows x 3 burners per row 3 May 1994 New England Power (NEP) 162 B&W wall fired 16/4 pulv Riley CCV 4 rows x 4 burners per row Salem Harbor Station, Unit 3 4 --. -- same, Unit 1 85 B&W wall fired 12/4 pulv B&W circular bnr 4 rows x 3 burners per row 5 --. -- same, Unit 4 (all) 400 Riley front fired 24 burners Rodenhuls& Vertoop 4 rows x 6 burners TTL 7 bnr (all) 6 June 1994 Northeastern Utilities, Holyoke Water 140 Riley front fired 16/4 pulv Riley CCV 4 rows x 4 burners per row Power Co., Mount Tom Power Plant 7 June 1994 Plbllc Service of New Hampshire, 280 B&W Cyclone 7 cyclones B& W coal cyclone 1 over 2, 2 over 2 Merrtmack Station, Unit 2 opposed fired 8 Nov-Dec. 1994 Amertcan Electrtc Power (AEP), 240 B& W front fired 24/6 pulv. B&W DRB-XCL modified 4 rows x 6 burners per row Appalachian Power, Glen Lyn Power partial division wall with Riley CCV spreaders Plant, Unit 6 9 Mar-Apr 1995 PEPCO, Chalk Pt. Power Plant, Unit 2 350 B&W opposed fired 24/6 pulv. Riley CCV 3 rows x 4 burners per row 10 May-Jun 1995 PEPCO, Chalk Pt. Power Plant, Unit 1 350 B&W opposed fired 24/6 pulv. Riley CCV 3 rows x 4 burners per row 11 May 1995 Nat.Power, Dldcot Power Plant, Unit 4 500 Brit. Babcock front fired 48/8 pulv. Brit. Babcock 10w-NOx 4 rows x 12 burners per row 12 May 1995 Nat.Power, Dldcot Power Plant, Unit 2 500 Brtt. Babcock front fired 48/8 pulv. Brtt. Babcock circular 4 rows x 12 burners per row 13 July 1995 Detroit Edison, Belle River Plant, Unit 1 600 B&W opposed fired 40/8 pulv. B&W DRB-XCL 4 rows x 5 burners per row |