Contents | 4 of 23

Comparison of Retinal Nerve Fiber Layer and Central Macular Thickness Measurements

Update Item Information
Title Journal of Neuro-Ophthalmology, June 2011, Volume 31, Issue 2
Date 2011-06
Language eng
Format application/pdf
Type Text
Publication Type Journal Article
Collection Neuro-ophthalmology Virtual Education Library: NOVEL http://NOVEL.utah.edu
Publisher Lippincott, Williams & Wilkins
Holding Institution Spencer S. Eccles Health Sciences Library, University of Utah, 10 N 1900 E SLC, UT 84112-5890
Rights Management © North American Neuro-Ophthalmology Society
ARK ark:/87278/s6x95hfx
Setname ehsl_novel_jno
ID 227170
Reference URL https://collections.lib.utah.edu/ark:/87278/s6x95hfx

Page Metadata

Title Comparison of Retinal Nerve Fiber Layer and Central Macular Thickness Measurements
Creator Watson, George M; Keltner, John L; Chin, Eric K; Harvey, Danielle; Nguyen, Audrey; Park, Susanna S
Affiliation Department of Ophthalmology & Vision Science, University of California Davis Eye Center, Sacramento, California
Abstract To compare the mean central macular thickness (CMT) and the mean average optic nerve retinal nerve fiber layer (RNFL) thickness in the eyes of patients with a history of optic neuritis and/or multiple sclerosis (MS) using 5 commercially available optical coherence tomography (OCT) instruments.Cross-sectional study including 46 patients (92 eyes) with a history of optic neuritis and/or MS. Both eyes were imaged on the same day with 5 OCT instruments: 1 time-domain OCT (Stratus) and 4 different Fourier-domain (spectral-domain) OCT (3D OCT-1000, Cirrus, RTVue-100, and Spectralis).Twenty-five patients (50 eyes) were included in the final analysis after excluding patients with diabetes, glaucoma, ocular hypertension, or retinal pathology and inadequate scan quality. Randomized block analysis of variance revealed statistically significant differences across instruments (P < 0.001) for both eyes for mean CMT and mean average optic nerve RNFL. When testing for significant differences in measurements from instrument to instrument, some difference was noted between the right and left eyes.Statistically significant differences exist among commercially available OCT instruments in measuring mean CMT and mean average RNFL thickness in patients with optic neuritis and/or MS. These findings likely result from the differences in data acquisition and segmentation algorithm software among OCT instruments. Awareness of these variations among OCT instruments will be important in using these instruments for clinical trials and management of patients with optic neuritis and/or MS.
Subject Adult; Older people; Analysis of Variance; Cross-Sectional Studies; Female; Fourier Analysis; Humans; Imaging, Three-Dimensional; Macula Lutea; Male; Middle Older people; Multiple Sclerosis; Optic Nerve; Optic Neuritis; Tomography, Optical Coherence
OCR Text Show
Format application/pdf
Holding Institution Spencer S. Eccles Health Sciences Library, University of Utah, 10 N 1900 E SLC, UT 84112-5890
Setname ehsl_novel_jno
ID 227150
Reference URL https://collections.lib.utah.edu/ark:/87278/s6x95hfx/227150
Back to Search Results