Title |
Comparison of 24-2 and 30-2 Perimetry in Glaucomatous and Nonglaucomatous Optic Neuropathies |
Creator |
Khoury, JM; Donahue, SP; Lavin, PJ; Tsai, JC |
Affiliation |
Department of Ophthalmology, Vanderbilt University School of Medicine, Nashville, Tennessee, USA. |
Abstract |
OBJECTIVE: To determine whether the 24-2 Humphrey visual field (HVF) (Humphrey, San Leandro, CA) strategy provides information comparable to that provided by the 30-2 strategy in patients with optic nerve disease. METHODS: In part A of the study, an occluder device was designed to cover the additional outer 22 points tested in the 30-2 strategy of 187 HVFs from neuro-ophthalmology patients with nonglaucomatous optic neuropathy and 206 HVFs from patients with glaucoma. This device converted the gray scale and probability plots of the 30-2 HVF to a 24-2 field. Fields were initially read using the occluder and then were read in a masked manner without the occluder and compared. In part B, 15 healthy volunteers performed both 30-2 and 24-2 HVFs. Testing time and global indices were compared. Ninety-five percent of the fields in the neuro-ophthalmology patients, 96% of the fields in patients under observation for suspected glaucoma, 98% of the fields in patients with ocular hypertension, and 100% of the fields in patients with glaucoma were read similarly with the 24-2 and 30-2 strategies. In the few cases in which a discrepancy was noted between the 24-2 and the 30-2 fields, appropriate clinical management would not have been compromised by using the 24-2 strategy. Most of these cases were in patients with idiopathic intracranial hypertension and very subtle nerve fiber bundle defects. The 24-2 strategy had a significantly lower pattern standard deviation (P < 0.01) and corrected pattern standard deviation (P = 0.05) than did the 30-2 strategy. In addition, the 24-2 strategy shortened the standard threshold testing time by 28% in normal volunteers (P < 0.0001 ). CONCLUSIONS: In most cases, the 24-2 testing strategy provides information comparable to that provided by the 30-2 strategy in a shorter time and with less variability. A 30-2 HVF may be warranted in patients under observation for evolving idiopathic intracranial hypertension. |
Subject |
Glaucoma/physiopathology; Humans; Optic Nerve Diseases/physiopathology; Perimetry; Prospective Studies; Reaction Time; Reference Values; Reflex, Pupillary/physiology; Retrospective Studies; Visual Fields/physiology |
Format |
application/pdf |
Publication Type |
Journal Article |
Collection |
Neuro-Ophthalmology Virtual Education Library: Journal of Neuro-Ophthalmology Archives: https://novel.utah.edu/jno/ |
Publisher |
Lippincott, Williams & Wilkins |
Holding Institution |
Spencer S. Eccles Health Sciences Library, University of Utah |
Rights Management |
© North American Neuro-Ophthalmology Society |
Setname |
ehsl_novel_jno |
ID |
224968 |
Reference URL |
https://collections.lib.utah.edu/ark:/87278/s6cz6d8d/224968 |