Validity of pulse oximetry during ventilator weaning of adult open heart surgery patients

Update Item Information
Publication Type dissertation
School or College College of Nursing
Department Nursing
Author Appleton, Rebecca Staker
Title Validity of pulse oximetry during ventilator weaning of adult open heart surgery patients
Date 1995-12
Description The aims of this research were (a) to evaluate the validity of pulse oximetry as a criterion of tissue oxygenation for nurses to use during ventilator weaning in adult open heart surgery patients, (b) determine which measure of tissue oxygenation (via pulse oximeter or arterial blood gas analyzer) is most valid to use during three phases of ventilator weaning. Little research has been done on ventilator weaning, even though it is an established nursing procedure in critical care units. Measurements of oxygen saturation via pulse oximetry are an established standard of care when weaning ventilator supported patients, yet no research-based data are available to support its widespread use. A descriptive, repeated-measures design was used to assess the agreement of blood oxygen saturation measured by three instruments during three phases of ventilator weaning. Study participants were 16 fair-skinned adults who had open heart surgery. Graphical analyses were computed to assess the agreement between the three blood oxygen saturations. Analyses of data suggest that mean pulse oximeter and mean arterial blood gas oxygen saturations differed by less than 1.7% during ventilator weaning. When mean oxygen saturations from the pulse oximeter and arterial blood gas analyzer were compared with the mean hemoximeter oxygen saturation both exceeded the 'standard' (hemoximeter) by more than 5%, making the measured agreement between them unacceptable. The findings of this study suggest that oxygen saturation measured via pulse oximetry is accurate when compared with data obtained via an arterial blood gas analyzer. However, it is not recommended that nurses abandon the practice of performing arterial blood gases to verify whether or not low SpO2 values measured by pulse oximeter are accurate. Wide fluctuations in Po2 can occur without corresponding changes in SpO2. One statistically significant relationship was found between SpO2 and Po2 r(16) =.63. No significant association was found among pH, Pco2, and core body temperature with SpO2 during ventilator weaning.
Type Text
Publisher University of Utah
Subject Heart - Surgery - Nursing; Oximetry; Breathing apparatus; Respirators (Medical equipment)
Subject MESH Thoracic Surgery; Oximetry; Ventilators, Mechanical
Dissertation Institution University of Utah
Dissertation Name PhD
Language eng
Relation is Version of Digital reproduction of "Validity of pulse oximetry during ventilator weaning of adult open heart surgery patients". Spencer S. Eccles Health Sciences Library.
Rights Management © Rebecca Staker Appleton.
Format Medium application/pdf
Format Extent 2,215,970 bytes
Identifier undthes,4283
Source Original: University of Utah Spencer S. Eccles Health Sciences Library (no longer available).
Master File Extent 2,216,022 bytes
ARK ark:/87278/s6833tv9
Setname ir_etd
ID 191317
Reference URL https://collections.lib.utah.edu/ark:/87278/s6833tv9
Back to Search Results