Cerebrospinal Fluid Pressure Reduction Results in Dynamic Changes in Optic Nerve Angle on Magnetic Resonance Imaging

Update Item Information
Title Cerebrospinal Fluid Pressure Reduction Results in Dynamic Changes in Optic Nerve Angle on Magnetic Resonance Imaging
Creator Ranliang Hu, John Holbrook, Nancy J. Newman, Valerie Biousse, Beau B. Bruce, Deqiang Qiu, John Oshinski, Amit M. Saindane
Affiliation Department of Radiology and Imaging Sciences (RH, DQ, JO, and AMS), Emory University School of Medicine, Atlanta, Georgia; Northside Radiology Associates (JH), Atlanta, Georgia; and Department of Ophthalmology (NJN, VB, BBB), Emory University School of Medicine, Atlanta, Georgia
Abstract Background: Optic nerve sheath tortuosity is a previously reported, but incompletely characterized, finding in idiopathic intracranial hypertension (IIH). We hypothesized that optic nerve angle (ONA), as a quantitative measure of tortuosity, would change dynamically with cerebrospinal fluid (CSF) pressure status of patients with IIH immediately before and after lumbar puncture (LP). Methods: Consecutive patients with suspected IIH referred for MRI and diagnostic LP were prospectively enrolled in this single institution, institutional review board-approved study. Each patient underwent a pre-LP MRI, diagnostic LP with opening pressure (OP) and closing pressure (CP), and then post-LP MRI all within 1 session. Sagittal and axial ONAs were measured on multiplanar T2 SPACE images by 2 neuroradiologists on pre- and post-LP MRI. Effects of measured pressure and CSF volume removal on changes in ONA were analyzed as was interrater reliability for ONA measurement. Results: Ten patients with IIH were included {all female, median age 29 (interquartile range [IQR] 25-32)}. All patients had elevated OP (median 37, IQR 34-41 cm H2O), and significantly reduced CP (median 18, IQR 16-19 cm H2O, P < 0.001) after CSF removal (IQR 13-16 mL). Within patients, mean ONAs (sagittal and axial) were significantly lower before (162 ± 9°, 163 ± 10°) than after (168 ± 7°, 169 ± 5°) LP (P = 0.001, 0.008, respectively). Interrater reliability was higher with sagittal ONA measurements (0.89) than axial (0.72). Conclusions: ONA changes with short-term CSF pressure reduction in patients with IIH, establishing optic nerve tortuosity as a dynamic process related to CSF status.
OCR Text Show
Date 2019-03
Language eng
Format application/pdf
Type Text
Publication Type Journal Article
Source Journal of Neuro-Ophthalmology, March 2019, Volume 39, Issue 1
Publisher Lippincott, Williams & Wilkins
Holding Institution Spencer S. Eccles Health Sciences Library, University of Utah, 10 N 1900 E SLC, UT 84112-5890
Rights Management © North American Neuro-Ophthalmology Society
ARK ark:/87278/s65b5rz2
Setname ehsl_novel_jno
ID 1595803
Reference URL https://collections.lib.utah.edu/ark:/87278/s65b5rz2
Back to Search Results