OCR Text |
Show AFRC 2008 AFRC 2008 AFRC 2008 40 CFR 60.18 General Requirements for Flares AFRC 2008 40 CFR 60.18 General Requirements for Flares 40 CFR 60.18 General Requirements for Flares Velocity Limit (fps) 1500 What about hydrogen or sonic flares?! 1000 500 0 0 500 1000 Flare Gas Heating Value (Btu/scf) 1500 The Problem in a Nutshell Operating parameter efficiency envelopes have not been developed to account for wind flare gas chemical composition stm/hc-ratio for smoke suppression Critical knowledge gaps are obstacles to measurable-operating-parameter-based flaring Best Practices to ensure high efficiency operation. Deliverables: Comprehensive and unambiguous quantification of the speciated emissions concentrations from elevated flares as a function of … ¾ flare gas composition ¾ flare/wind momentum flux ratio ¾ steam rate Comprehensive and unambiguous quantification of flare/wind low momentum flux ratio inefficiencies ¾ Downstream "best practice" no flaring purge and pilot only operation ¾ Upstream field flare operation Comprehensive and unambiguous quantification of oversteaming inefficiencies ¾ Downstream operations Identification of measurable operating parameter based "Best Practices" to ensure high efficiency operation of upstream and downstream elevated flares Principal Investigators John Pohl Peter Gogolek Bob Schwartz Jim Seebold Virginia Polytechnic Institute and State University John Zink Company LLC Natural Resources Canada CANMET Energy Technology Centre Chevron(Ret) Effect of Wind ... ? Buoyant- Wake-Mixing Transition Effect of Steam ... ? International Flare Consortium Timeline 2004 2005 2006 2007 2008 2009 2009 T NRCan, Ottawa T TCEQ, Austin T JZ, Tulsa T EPA, RTP T NRCan, Ottawa T Chevron, San Francisco T Shell, Houston T API, Washington V NRCan, Ottawa "Phase III" (TBD & not included) Full-scale verification & validation of remote measurement technique at the John Zink Flare Test Facility Friday 05-09 IFC Update Tests Without Steam All completed last fall. Extinction Tests with CO2 A new test series has started. Natural gas, Propylene and Propane tests are complete. Ethylene will be arriving shortly. Purge & Pilot Tests Tests complete. Tests with Steam Analysis of steam flow rates and verification trials continue. Refinery Relief Gas Testing The design company is in the process of sending out the updated P&I drawing and bill of material. Low BTU Gas Testing Not yet begun, scheduled for May-June 2008. BTEX, Hexane tests Quotes are being received for a BTEX heater and the benzene/toluene mix. Friday 05-09 IFC Schedule Update International Flare Consortium Total British Petroleum ExxonMobil Chevron Saudi Aramco NovaChem John Zink Shell DuPont |