Description |
Magnetic fields are permeable to the biological tissues and can induce electric field in the conductive structures. Some medical devices take advantage of this ability to transfer energy from the source to the receiving site without direct contact. Prosthetic devices such as retinal implants use time-varying magnetic field to achieve wireless power transfer to the implanted magnetic coil. However, devices such as magnetic stimulators use the induction principle to create an electric field at the stimulation site. Efficiency of these devices is primarily dependent on the design of the magnetic coils. Therefore, in this work, we designed and validated efficient magnetic coils for wireless power transfer to implanted devices and magnetic stimulation of the peripheral nerves. Typical wireless power transfer (WPT) systems uses two-coil based design to achieve contactless power transfer to the implanted electronics. These systems achieve low power transfer efficiency (< 30%) and frequency bandwidth. Moreover, efficient wireless system requires high coupling and load variation tolerance during device operation. To design an electromagnetic safe WPT system, the power absorbed by the tissue and radiated field due to the proximal magnetic coils needs to be minimized. In this work, we proposed a multi-coil power transfer system which solves some of the current challenges. The proposed multi-coil WPT system achieves more than twice the power transfer efficiency, controllable voltage gain, wider frequency bandwidth, higher tolerance to coupling and load variations, lower absorbed power in the tissue and lower radiated field from the magnetic coil than a comparable two-coil system. In this work, we have developed analytic models of the multi-coil WPT system and validated the accuracy of the solutions using experiments. Magnetic coils play an important role in controlling the distribution of induced electric field inside the nerve during magnetic stimulation. In the past, homogeneous models were used to estimate the field profile inside conductive tissue due to the time varying current in the magnetic coil. Moreover, the effect of the surrounding media and stimulation mechanisms was understudied, which limits the optimization accuracy of the magnetic coils. In this work, we developed anatomically correct tissue models to study the effect of tissue heterogeneity and the surrounding media on the induced electric field. We also developed an optimization algorithm for designing energy efficient cm-size magnetic coils, that were then used for ex-vivo magnetic stimulation of the frog's sciatic nerve. |