Description |
High-count microelectrode arrays implanted in peripheral nerves could restore motor function after spinal cord injury or sensory function after limb loss via electrical stimulation. The same device could also help restore volitional control to a prosthesis-using amputee, or sensation to a Spinal cord Injury (SCI) patient, via recordings from the still-viable peripheral nerves. The overall objective of these dissertations studies is to improve the usefulness of intrafascicular electrodes, such as the Utah Slanted Electrode Array (USEA), for neuroprosthetic devices for limb loss or spinal cord injury patients. Previous work in cat sciatic nerve has shown that stimulation through the USEA can remain viable for months after implant. However, stimulation parameters were not stable, and recordings were lost rapidly and were subject to strong contamination by myoelectrical activity from adjacent muscles. Recent research has shown that even when mobility is restored to a patient, either through prosthesis or functional electrical stimulation, difficulties in using the affected limbs arise from the lack of sensory input. In the absence of the usual proprioceptive and cutaneous inputs from the limb, planning and executing motions can be challenging and sometimes lead to the user's abandonment of prostheses. To begin to address this need, I examined the ability of USEAs in cat hindlimb nerves to activate primary sensory fibers by monitoring evoked potentials in somatosensory cortex via skull-screw electrodes. I iv also monitored evoked EMG responses, and determined that it is possible to recruit sensory or motor responses independently of one another. In the second study of this dissertation, I sought to improve the long-term stability of USEAs in the PNS by physically and electrically stabilizing and protecting the array. To demonstrate the efficacy of the stabilization and shielding technique, I examined the recording capabilities of USEA electrodes and their selectivity of muscle activation over the long term in cat sciatic nerve. In addition to long-term viability, clinically useful neuroprosthetic devices will have to be capable of interfacing with complex motor systems such as the human hand. To extend previous results of USEAs in cat hindlimb nerves and to examine selectivity when interfacing with a complex sensorimotor system, I characterized EMG and cortical somatosensory responses to acute USEA stimulation in monkey arm nerves. Then, to demonstrate the functional usefulness of stimulation through the USEA. I used multi-array, multi-electrode stimulation to generate a natural, coordinated grasp. |