Design, characterization, and testing of skin-stretch feedback integrated into a game controller

Update Item Information
Title Design, characterization, and testing of skin-stretch feedback integrated into a game controller
Publication Type thesis
School or College College of Engineering
Department Mechanical Engineering
Author Caswell, Nathaniel Alexis
Date 2013-12
Description Haptic feedback in modern game controllers is limited to vibrotactile feedback. The addition of skin-stretch feedback would significantly improve the type and quality of haptic feedback provided by game controllers. Skin-stretch feedback requires small forces (around a few newtons) and translations (as small as 0.5 mm) to provide identifiable direction cues. Prior work has developed skin-stretch mechanisms in two form factors: a flat form factor and a tall but compact (cubic) form factor. These mechanisms have been shown to be effective actuators for skin-stretch feedback, and are small enough to fit inside of a game controller. Additional prior work has shown that the cubic skin-stretch mechanism can be integrated into a thumb joystick for use with game controllers. This thesis presents the design, characterization, and testing of two skin-stretch game controllers. The first game controller provides skin stretch via a 2-axis mechanism integrated into its thumb joysticks. This controller uses the cubic skin-stretch mechanism to drive the skin stretch. Concerns that users' motions of the joystick could negatively impact the saliency of skin stretch rendered from the joystick prompted the design of a controller that provides 2-axis skin stretch to users' middle fingers on the back side of the controller. Two experiments were conducted with the two controllers. One experiment had participants identify the direction of skin stretch from a selection of 8 possible directions. This test compared users' accuracies with both controllers, and with five different finger restraints on the back-tactor controller. Results show that users' identification accuracy was similar across feedback conditions. A second experiment used skin stretch to rotationally guide participants to a randomized target angle. Three different feedback strategies were tested. Results showed that a strategy called sinusoidal feedback, which provided feedback that varied in frequency and amplitude as a function of the user's relative position to the tactor, performed significantly better on all performance metrics than the other feedback strategies. It is important to note that the sinusoidal feedback only requires two 1-axis skin-stretch actuators, which are spatially separated, in order to provide feedback. The other lower performing feedback strategies used two 2-axis skin-stretch actuators.
Type Text
Publisher University of Utah
Subject Game controller; Haptics; Skin stretch; Tactile
Dissertation Institution University of Utah
Dissertation Name Master of Science
Language eng
Rights Management Copyright © Nathaniel Alexis Caswell 2013
Format application/pdf
Format Medium application/pdf
Format Extent 1,751,327 bytes
Identifier etd3/id/2672
ARK ark:/87278/s6j99fk0
Setname ir_etd
ID 196247
Reference URL https://collections.lib.utah.edu/ark:/87278/s6j99fk0
Back to Search Results