1 - 25 of 17
Number of results to display per page
CreatorTitleDescriptionSubjectDate
1Postoperative sterile endophthalmitis (TASS) associated with the memorylensOlson, Randall J.; Mamalis, Nick; Spencer, Terrence S.Postoperative sterile endophthalmitis (TASS) associated with the memorylensPURPOSE: To report 10 cases of delayed-onset acute intraocular inflammation following cataract extraction and posterior chamber implantation of the MemoryLens(R) intraocular lens (IOL). SETTING: John A. Moran Eye Center, Department of Ophthalmology, University of Utah, Salt Lake City, Utah, USA. MET...Memory Lens; Toxic Anterior Segment Syndrome; Retrospective Studies; adverse effects2000-12
2Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lensesOlson, Randall J.; Spencer, Terrence S.; Mamalis, NickThree-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lensesPURPOSE: To compare the 3-year performance of the 3-piece AcrySof (Alcon) and the SI-40 silicone (Allergan) intraocular lenses (IOLs). SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: In this retrospective study, patients with no complications and at least a...Acrylic Resins; Silicone Elastomers; Prosthesis Design; Postoperative Complications; Patient Satisfaction; Cataract2002-07
3Effect of lens edge design versus anterior capsule overlap on posterior capsule opacificationOlson, Randall J.Effect of lens edge design versus anterior capsule overlap on posterior capsule opacificationPURPOSE: To determine whether lens edge design or anterior capsule overlap on the intraocular lens (IOL) has greater effect on posterior capsule opacification (PCO). DESIGN: Retrospective cohort clinical study. METHODS: Retrospective. SETTING: Academic clinical practice. PATIENT POPULATION: The pati...Posterior Capsular Opacification' Intraocular Lens; Anterior Capsular Opacification; Acrylic Lenses; Silicone Lenses2004-10
4Efficacy and wound-temperature gradient of WhiteStar technology phacoemulsification through a 1.2 mm incisionOlson, Randall J.Efficacy and wound-temperature gradient of WhiteStar technology phacoemulsification through a 1.2 mm incisionPURPOSE: To evaluate the efficacy and wound-temperature gradients of WhiteStar micropulse technology using bimanual phacoemulsification without an irrigation sleeve through a 1.2 mm incision. SETTING: Island Eye Surgicenter, Carle Place, New York, USA. METHODS: Ten patients had bimanual phacoemulsif...Endothelium, Corneal; Surgical Procedures; Lens Implantation; Wound Temperature gradient2003-06
5Glistenings with long-term follow-up of the Surgidev B20/20 polymethylmethacrylate intraocular lensOlson, Randall J.Glistenings with long-term follow-up of the Surgidev B20/20 polymethylmethacrylate intraocular lensPURPOSE: To compare patient satisfaction with vision 12 months after implantation of a silicone or acrylic foldable intraocular lens (IOL). SETTING: John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS: Selection criteria included patients who had uneventfu...Phacoemulsification; Lens Implantation, Intraocular; Glare2001-10
6Comparison of the effects of viscoelastic agents on clinical properties of the Unfolder lens injection systemOlson, Randall J.Comparison of the effects of viscoelastic agents on clinical properties of the Unfolder lens injection systemPURPOSE: To evaluate the effect of 7 viscoelastic materials on the physical properties of the Unfolder lens injection system. SETTING: John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City, Utah, USA. METHODS: New sterile SI-40NB intraocular lenses (IOLs) were loaded into t...Lenses, Intraocular; Materials Testing; Hyaluronic Acid; Equipment Failure Analysis1999-07
7Comparison of thermal features associated with 2 phacoemulsification machinesOlson, Randall J.Comparison of thermal features associated with 2 phacoemulsification machinesPURPOSE: To determine the thermal characteristics of the Legacy Advantec and Sovereign WhiteStar phacoemulsification machines during different clinically relevant scenarios. SETTING: In vitro study. METHODS: In water, temperature was recorded continuously on the sleeve in an artificial chamber, and ...Cataracts; Wound Burns; Thermal Characteristics2006-02
8Wound complications associated with incision enlargement for foldable intraocular lens implantation during cataract surgeryOlson, Randall J.Wound complications associated with incision enlargement for foldable intraocular lens implantation during cataract surgeryPURPOSE: To determine the relationship between various intraocular lens (IOL) types and the incidence of unwanted light images. SETTING: The Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: A telephone questionnaire was administered to 302 postoperative patients who had rece...Cararact Surgery; Incision Enlargement; Wound Complications; Vision Disorders2000-06
9Legacy AdvanTec and Sovereign WhiteStar: a wound temperature studyOlson, Randall J.Legacy AdvanTec and Sovereign WhiteStar: a wound temperature studyPURPOSE: To assess the wound temperature of the Sovereign WhiteStar (S-WS) (AMO) and Legacy AdvanTec (L-ADV) (Alcon) phacoemulsification systems. SETTING: John A. Moran Eye Center, Health Sciences Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Phacoemulsification using 20-gauge, 30-...Eye Burns; Wound Temperature; Phacoemulsification Systems2004-05
10Cataract surgery complications in 1 year at an academic institutionOlson, Randall J.; Crandall, Alan S.; Pingree, Michael F.Cataract surgery complications in 1 year at an academic institutionPURPOSE: To delineate all complication rates of cataract surgery and define normative rates, trends, and outliers as part of continuous quality management. SETTING: John A. Moran Eye Center, University of Utah Health Sciences Center, Salt Lake City, Utah, USA. METHODS: All cataract surgeries done at...Intraoperative Complications/Epidemiology; Adverse Effects; Cataract Surgery1999-05
11Clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lensesOlson, Randall J.Clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lensesPURPOSE: To determine the clinical differences between three-piece (3P) and single-piece (SP) truncated hydrophobic acrylic intraocular lenses (IOL). DESIGN: Retrospective cohort clinical study. METHODS: The setting was an academic clinical practice. The patient population consisted of subjects with...Lenses, Intraocular; Patient Satisfaction; Postoperative Complications; Prosthesis Design; Visual Acuity2003-10
12Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar Technology in eyes with dense cataractOlson, Randall J.Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar Technology in eyes with dense cataractPURPOSE: To present a series of patients who had 21-gauge microphacoemulsification using Sovereign WhiteStar technology. SETTING: John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City, Utah, USA. METHODS: Eighteen consecutive patients with cataracts judged to be 3+ or 4+ on...Cataract; Microsurgery; Phacoemulsification; Postoperative Complications; Visual Acuity2004-01
13Cohort study of 27 cases of endophthalmitis at a single institutionOlson, Randall J.Cohort study of 27 cases of endophthalmitis at a single institutionPURPOSE: To identify potential risk factors associated with post-cataract surgery bacterial endophthalmitis. SETTING: The John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: This retrospective cohort study consisted of patients who had surgery for cataract(s) at this eye hospital. A 10% sa...Cataract Extraction; Endophthalmitis; Wound Healing; Risk Factors2005-04
14Comparison of patient satisfaction after uncomplicated cataract surgery between the silicone AMO SI-30/40 and the acrylic Alcon MA30BA and MA60BA foldable intraocular lensesOlson, Randall J.Comparison of patient satisfaction after uncomplicated cataract surgery between the silicone AMO SI-30/40 and the acrylic Alcon MA30BA and MA60BA foldable intraocular lensesPURPOSE: To compare patient satisfaction with vision 12 months after implantation of a silicone or acrylic foldable intraocular lens (IOL). SETTING: John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS: Selection criteria included patients who had uneventfu...Patient Satisfaction; Lenses, Intraocular; Silicone Elastomers; Biocompatible Materials2001-10
15Intraoperative crystallization on the intraocular lens surfaceOlson, Randall J.; Crandall, Alan S.; Caldwell, Karin D.; Jensen, Michael K.Intraoperative crystallization on the intraocular lens surfacePURPOSE: To report a physician survey, laboratory studies, and clinical observations of intraoperative crystallization on the surface of the intraocular lens (IOL). METHOD: We sent a survey to all ophthalmologists in the states of Wyoming, Idaho, Montana, Utah, and Colorado asking whether crystalliz...Cataract Extraction; Intraoperative Complications; Risk Factors1998-08
16Update on a long-term, prospective study of capsulotomy and retinal detachment rates after cataract surgeryOlson, Randall J.Update on a long-term, prospective study of capsulotomy and retinal detachment rates after cataract surgeryPURPOSE: To evaluate the retinal detachment risks and neodymium:YAG (Nd:YAG) capsulotomy rates associated with different cataract approaches and intraocular lens (IOL) styles in a long-term,prospective clinical study. SETTING: Clinical practice of 1 ophthalmologist, Fort Collins, Colorado, USA. METH...Cataract Extraction; Laser Therapy; Retinal Detachment; Risk Factors2000-07
17Penetrating keratoplasty for keratoconus: a long-term review of results and complicationsOlson, Randall J.; Pingree, Michael F.; Lundergan, Maureen K.Penetrating keratoplasty for keratoconus: a long-term review of results and complicationsPURPOSE: To study the long-term complications of penetrating keratoplasty (PKP) to evaluate current recommendations to patients with keratoconus. SETTING: John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Retrospective study of all PKP procedures for keratoconus performe...Visual Acuity; Refraction, Ocular; Keratoconus; Astigmatism2000-07
1 - 25 of 17