Noninvasive determination of tissue parameters in magnetic resonance guided high intensity focused ultrasound for breast cancer therapy

Update Item Information
Publication Type dissertation
School or College College of Engineering
Department Biomedical Engineering
Author Wang, Yi
Title Noninvasive determination of tissue parameters in magnetic resonance guided high intensity focused ultrasound for breast cancer therapy
Date 2014-12
Description Magnetic resonance guided high intensity focused ultrasound (MRgHIFU) is a promising minimal invasive thermal therapy for the treatment of breast cancer. This study develops techniques for determining the tissue parameters - tissue types and perfusion rate - that influence the local temperature during HIFU thermotherapy procedures. For optimal treatment planning for each individual patient, a 3D volumetric breast tissue segmentation scheme based on the hierarchical support vector machine (SVM) algorithm was developed to automatically segment breast tissues into fat, fibroglandular tissue, skin and lesions. Compared with fuzzy c-mean and conventional SVM algorithm, the presented technique offers tissue classification performance with the highest accuracy. The consistency of the segmentation results along both the sagittal and axial orientations indicates the stability of the proposed segmentation routine. Accurate knowledge of the internal anatomy of the breast can be utilized in the ultrasound beam simulation for the treatment planning of MRgHIFU therapy. Completely noninvasive MRI techniques were developed for visualizing blood vessels and determining perfusion rate to assist in the MRgHIFU therapy. Two-point Dixon fat-water separation was achieved using a 3D dual-echo SSFP sequence for breast vessel imaging. The performances of the fat-water separation with various readout gradient designs were evaluated on a water-oil phantom, ex vivo pork sample and in vivo breast imaging. Results suggested that using a dual-echo SSFP readout with bipolar readout gradient polarity, blood vasculature could be successfully visualized through the thin-slab maximum intensity projection SSFP water-only images. For determining the perfusion rate, we presented a novel imaging pulse sequence design consisting of a single arterial spin labeling (ASL) magnetization preparation followed by Look-Locker-like image readouts. This flow quantification technique was examined through simulation, in vitro and in vivo experiments. Experimental results from a hemodialyzer when fitted with a Bloch-equation-based model provide flow measurements that are consistent with ground truth velocities. With these tissue properties, it is possible to compensate for the dissipative effects of the flowing blood and ultimately improve the efficacy of the MRgHIFU therapies. Complete noninvasiveness of these techniques allows multiple measurements before, during and after the treatment, without the limitation of washout of the injected contrast agent.
Type Text
Publisher University of Utah
Dissertation Institution University of Utah
Dissertation Name Doctor of Philosophy
Language eng
Rights Management Copyright © Yi Wang 2014
Format Medium application/pdf
Format Extent 5,091,208 bytes
Identifier etd3/id/3342
ARK ark:/87278/s6x66w57
Setname ir_etd
ID 196907
Reference URL https://collections.lib.utah.edu/ark:/87278/s6x66w57
Back to Search Results